17th Edition IEE Wiring Regulations: Explained and Illustrated, Eighth Edition | by Brian Scaddan | ISBN: 9780750687201. Electrical Safety Guide. Earthing Techniques. PROTECTION AGAINST ELECTRIC SHOCK. Circuit Design Procedure.

November 25, 2009 by kutenk · 1 Comment
Filed under: Engineering Books 

17th Edition IEE Wiring Regulations: Explained and Illustrated, Eighth Edition

by Brian Scaddan
ISBN:9780750687201

Focusing on common misconceptions in the application of the Wiring Regulations, this book explains in clear language those parts of the Regulations that most need simplifying, and outlines the correct procedures to follow and those to avoid.

Get this Book by clicking below:

Get Book Now

17th Edition IEE Wiring Regulations—Explained and Illustrated, Eighth Edition







Preface
Introduction
Chapter 1 – Fundamental Requirements for Safety
IEE WIRING REGULATIONS (IEE REGULATIONS PART 1 AND CHAPTER 13)
THE HEALTH AND SAFETY AT WORK ACT 1974
THE ELECTRICITY AT WORK REGULATIONS 1989
AN EXTRACT FROM THE BUILDING REGULATIONS APPROVED DOCUMENT ‘P’

Chapter 2 – Earthing
DEFINITIONS USED IN THIS CHAPTER
EARTH: WHAT IT IS, AND WHY AND HOW WE CONNECT TO IT
EARTH ELECTRODE RESISTANCE
EARTHING IN THE IEE REGULATIONS (IEE REGULATIONS CHAPTER 4, SECTION 411)
EARTHING SYSTEMS (IEE REGULATIONS DEFINITIONS (SYSTEMS))
EARTH FAULT LOOP IMPEDANCE
DETERMINING THE VALUE OF TOTAL LOOP IMPEDANCE
ADDITIONAL PROTECTION


Chapter 3 – Protection
DEFINITIONS USED IN THIS CHAPTER
WHAT IS PROTECTION?
PROTECTION AGAINST ELECTRIC SHOCK (IEE REGULATIONS CHAPTER 41)
PROTECTION AGAINST OVERCURRENT (IEE REGULATIONS CHAPTER 43 AND DEFINITIONS)
PROTECTION AGAINST OVERVOLTAGE (IEE REGULATIONS SECTION 443)
PROTECTION AGAINST UNDERVOLTAGE (IEE REGULATIONS SECTION 445)

Chapter 4 – Isolation Switching and Control
DEFINITIONS USED IN THIS CHAPTER
ISOLATION AND SWITCHING (IEE REGULATIONS SECTION 537)

Chapter 5 – Circuit Design
DEFINITIONS USED IN THIS CHAPTER
DESIGN PROCEDURE
DESIGN CURRENT
NOMINAL SETTING OF PROTECTION
VOLTAGE DROP (IEE REGULATIONS 525 AND APPENDIX 12)
SHOCK RISK (IEE REGULATIONS SECTION 411)
THERMAL CONSTRAINTS (IEE REGULATIONS SECTION 543)
EXAMPLE OF USE OF THE ADIABATIC EQUATION
AN EXAMPLE OF CIRCUIT DESIGN
ASSESSMENT OF GENERAL CHARACTERISTICS
SIZING THE MAIN TAILS
SIZING THE KILN CIRCUIT CABLE

Chapter 6 – Inspection and Testing
DEFINITIONS USED IN THIS CHAPTER
TESTING SEQUENCE (PART 7)

Chapter 7 – Special Locations IEE Regulations Part 7
INTRODUCTION
BS 7671 SECTION 701: BATHROOMS, ETC
BS 7671 SECTION 702: SWIMMING POOLS
BS 7671 SECTION 703: HOT AIR SAUNAS
BS 7671 SECTION 704: CONSTRUCTION SITES
BS 7671 SECTION 705: AGRICULTURAL AND HORTICULTURAL LOCATIONS
BS 7671 SECTION 706: RESTRICTIVE CONDUCTIVE LOCATIONS
BS 7671 SECTION 708: CARAVAN AND CAMPING PARKS
BS 7671 SECTION 709: MARINAS
BS 7671 SECTION 711: EXHIBITIONS, SHOWS AND STANDS
BS 7671 SECTION 712: SOLAR PHOTOVOLTAIC (PV) SUPPLY SYSTEMS
BS 7671 SECTION 717: MOBILE OR TRANSPORTABLE UNITS
BS 7671 SECTION 721: CARAVANS AND MOTOR CARAVANS
BS 7671 SECTION 740: AMUSEMENT DEVICES, FAIRGROUNDS, CIRCUSES, ETC
BS 7671 SECTION 753: FLOOR AND CEILING HEATING SYSTEMS

Appendix 1 – Problems
Appendix 2 – Answers to Problems


For 1000+ more Engineering Books & Electrical Engineering Books, click below:

Science & Engineering Books
Business & Management Books
Computer Books

  • Share/Bookmark